[GP1.058] High density operation with Lower Hybrid waves in FTU tokamak

V. Pericoli Ridolfini, F. Mirizzi, L. Panaccione, S. Podda (ENEA CR FRASCATI - CP 65 00044 FRASCATI (Roma) - Italy), FTU Team

Since April 2001 the lower hybrid (LH) radiofrequency system in FTU (6 gyrotrons @ f=8 GHz) can deliver to the plasma about 2 MW through two equal launchers with a reflection coefficient = 10%. This value is close to the target value of 2.2 MW (net power density of 6.2 kW/cm2 on the waveguides mouth) which could be reached after further conditioning of the grill and of the transmission lines. In high density plasmas (line density *1*1020 m-3), high magnetic field (BT=7.2 T), with PLH=2 MW we drive about 75% of the total current (Ip=500 kA) and stabilise fully the sawteeth activity. The central electron temperature Te0 increases from 1.6 to 3.3 keV (steady), and the neutron rate by about 10 times. Analysis of these pulses with effective electronic heating will be presented. In post-pellet plasmas ( *6*1020 m-3), good coupling of the LH is achieved with the launcher almost flush to the walls, due to the very dense scrape off-layer. The perturbation here induced by the pellet imposes a delay to the LH of only 20 ms. The exact location of the launcher is critical in these regimes, because the high N|| (parallel index of refraction) requested (N||>2.3) for a good penetration of the waves makes more problematic a good coupling all along the poloidal extension of the grill.

Part G of program listing